The cutting machine is electrified but it can't start. What's the matter?

Aug 08, 2018

The cutting machine is electrified but it can't start. What's the matter?


The cutting machine is electrified but it can't start. What's the matter?

Fault analysis and Troubleshooting:

1, the cutter mode setting switch is located at the horizontal position to lock the oil path (to turn the cutter mode fixed switch to the vertical direction).

2. Motor steering error (replacing two phases of motor).

3, the contact of the work switch is bad, and the thread ends fall off.

4, the solenoid valve coil burned (replace the coil or the entire solenoid valve).

5. The valve core of the solenoid valve is stuck (cleaning valve core)

6, the stroke adjustment handle is loose (reset the knife die)

  